Magnetically shielded room (MSR)

VACOSHIELD - Measure Precisely without any Disturbance

MSRs are used for shielding applications that are very sensitive to magnetic sources of interference. Our VACOSHIELD® rooms are a proven solution that has become an industry standard.

Benefits:

  • More than 170 MSRs have successfully been installed worldwide
  • Preselection of in-house produced top quality material lots
  • Excellent R & D, engineering and customer support
  • Great design flexibility

 

Shielding of highly sensitive medical and scientific magnetic field sensors from external magnetic interference fields.

Typically, our standard shielding rooms are used to shield MEG (Magnetoencephalography) devices that allow measurement of brain signals and are used, for example, for epilepsy patients.

Among other applications, the VACOSHIELD solution is also increasingly used to shield sensors based on optically pumped magnetometer (OPM) technology. 

Values determined on real VACOSHIELD Advanced 3x4 m (MUMETALL-Aluminum-MUMETALL®). The shielding factor of an MSR depends significantly on the amplitude of magnetic interference fields.
Our MSRs are qualified by default at B=1 µTRMS, at higher flux densities the shielding factors are significantly higher (experimentally tested up to B≤100 µTRMS).

Bespoke and powerful MSRs available for any requirement.

We are looking forward to your inquiry: Lela.Bauer@vacuumschmelze.com

 

  • Our VACOSHIELD MSRs have high design flexibility due to a modular design.
  • Room size and shielding performance is easily adaptable to customer needs.
  • Fast construction and set up times.
  • Easy relocation of MSRs possible to other sites.

 

Shielding of highly sensitive medical and scientific magnetic field sensors from external magnetic interference fields.

Typically, our standard shielding rooms are used to shield MEG (Magnetoencephalography) devices that allow measurement of brain signals and are used, for example, for epilepsy patients.

Among other applications, the VACOSHIELD solution is also increasingly used to shield sensors based on optically pumped magnetometer (OPM) technology. 

Values determined on real VACOSHIELD Advanced 3x4 m (MUMETALL-Aluminum-MUMETALL®). The shielding factor of an MSR depends significantly on the amplitude of magnetic interference fields.
Our MSRs are qualified by default at B=1 µTRMS, at higher flux densities the shielding factors are significantly higher (experimentally tested up to B≤100 µTRMS).

Bespoke and powerful MSRs available for any requirement.

We are looking forward to your inquiry: Lela.Bauer@vacuumschmelze.com

 

  • Our VACOSHIELD MSRs have high design flexibility due to a modular design.
  • Room size and shielding performance is easily adaptable to customer needs.
  • Fast construction and set up times.
  • Easy relocation of MSRs possible to other sites.

 

Contact Us Think Global - Act Local

We are looking forward to support you.

Find Your Local Support

Contactform